-40%

US Vet Veterinary ICU CCU Patient Monitor NIBP SPO2 ECG TEMP RESP PR Vital Signs

$ 234.43

Availability: 276 in stock
  • Monitor Parameters: Blood Pressure - NIBP
  • Intended Use/Discipline: Cardiology
  • MPN: Does Not Apply
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Modified Item: No
  • Brand: Unbranded
  • Expiration Date: Brand New
  • Return shipping will be paid by: Seller
  • Item must be returned within: 30 Days
  • Custom Bundle: No
  • Country/Region of Manufacture: China
  • Restocking Fee: No
  • Condition: New
  • All returns accepted: Returns Accepted

    Description

    Description:
    This monitor is suitable for felines,canines and other animals, may monitor the physical parameters, such as electrocardiograph (ECG), noninvasive blood pressure (NIBP), oxygen saturation (SpO₂), respiration rate (Resp), body temperature (Temp) and so on, can display maximum 8 waveforms and all information of the parameters monitored in the same screen.
    Features:
    Ergonomic design, Lightweight, compact and portable, convenient for use.
    12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
    Unique digital SPO2 technology can work accurate during motion and low perfusion.
    Anti AC &
    high-frequency electrosurgical

    defibrillator

    s interference
    .
    Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and other
    Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
    ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation.
    Audible & visual alarm available, adjustable.
    Super long life rechargeable Lithium battery up to 4 hours of working time
    This monitor provides the function of computation for 21 kinds of medicines and the titration table.
    It is providing fast and reliable measurements for the veterinary patients. The measuring size of patients animals range from the small to big animals such as cats dogs, horses. It is suitable for vet hospital, clinic, and animal labs.
    Standard configuratio
    n:
    ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery.
    ECG
    :
    Full lead: I, II, III, AVL, AVR, AVF, V
    Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
    Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
    Band width: 0.05Hz-100Hz(3dB)
    Heart rate:
    Scope: 15 times/minute to 300 times/minutes
    Accuracy: ±1 time/minute
    Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
    Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
    Accuracy: Error rate < 20%
    Undetected rate < 20%
    ST section
    Scope: ±0.8mV
    Precision :
    < ±
    0.05mV
    SpO2
    :
    Detection scope: 0%-100%
    Accuracy:±1% 90%-100%;±2% 70%-89%
    NIBP:
    Theory Electric oscillator
    Manual selection:9.3kPa
    (
    70 mmHg
    ),
    13.3kPa
    (
    100 mmHg
    )
    16.0kPa
    (
    120 mmHg
    )
    18.6kPa
    (
    140 mmHg
    ),
    20.0kPa

    150 mmHg
    ),
    21.3kPa
    (
    160 mmHg
    ),
    Automatic detection period:1 minute to 240 minutes.
    Detection accuracy:
    Static pressure: ±3mmHg
    Pulse rate: ±2%
    Respiration Rate:
    Measurement Range:0 ~ 150 BrPM
    Resolution:1 BrPM
    Accuracy:0

    6 BrPM: unspecified;7

    150 BrPM:
    ±
    2 BrPM
    Temperature:
    Channel:2
    Measure and Alarm Range:0 ~ 50

    Resolution:0.1

    Accuracy(no sensor):
    ±
    0.1

    (0
    ℃ –
    50

    )
    Environment Specification:
    Operating Temp: 0 to 05°c
    Storage Temp: -20 to +50°c
    Relative Humidity: 15 to 95%(Operating), 15 to 95%(Storage)
    Power Supply:100~240 VAC, 50/60 Hz, Pmax=90VA Fuse T1.5A
    FDA Disclaimer:
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    ARTG NO: 278908 ARTG Number: 278908
    Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603)
    This item has been cleaned and treated according to the manufacturer's instructions.
    The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013).