Protable ICU CCU 6-parameter Patient Monitor Medical Monitor Health Care USA
$ 221.23
- Description
- Size Guide
Description
DetailsDescription:
Model: RPM-9000A
Features:
Ergonomic design, portable, convenient for use
12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SPO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical & defibrillator’s interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Optional software upgrading based on USB
Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language i.e. English, Spanish, Turkish.
Super long life rechargeable Lithium battery upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
Standard configuration:
ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
Optional:
Dual TEMP
Dual IBP
ETCO2 (side stream)
Thermal recorder
Wall mount
Trolley
Specification:
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ±0.8mV
Precision : < ±0.05mV
SpO2
Detection scope: 0%-100%
Accuracy ±1% 90%-100%
±2% 70%-89%
NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20℃~50℃
Accuracy: ±0.2℃
Invasive blood pressure (optional)
Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
Packing List:
Iitem
NO.
Content
Qty
Remark
Standard Configuration
1
Main Unit
1
2
Power cable
1
3
ECG Cable
1
Integrated
4
NIBP Cuff
1
Adult
5
External NIBP Hose
1
6
SPO2 Probe
1
7
Temperature Probe
1
8
Disposable Electrodes
1
9
Packing List
1
10
Grounding wire
1
11
Operator's Manual
1
12
13
14
15
Optional
1
IBP kit
2
EtCO2 Set
3
Built-in Recorder
4
IBP kit
5
PAYMENT
1.We accept payment by
PayPal
. PayPal enables you to make payment
quickly and securely online.
2.We accept payment via PayPal.Please pay the money within 5
days
after the auction ended. 3.
Please offer home or mobile phone when the item's Value exceeds
100 (USD, EUR, AUD, GBP) so that we can make sure you get the
item
safely.
FDA Disclaimer
The following FDA Disclaimer is required for all eBay listing i
n
Healthcare category and is included for REFERENCE:
The saleof this item may be subject to regulation by the U.S. Food andDrug Administration and state and local regulatory agencies.Ifso, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.(The seller’s name: Jenny Liu City: Beijing State: Beijing Country: China Telephone number: 86-18789632541)
The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). You can consult with the FDA's Center for Devices and Radiological Health.
This item has been cleaned and treated according to the manufacturer's instructions.
SHIPPING
All items will be shipped within 2 business day
.More than 200$,express ship via DHL/UPS/EMS,
It takes approximately 5-7 days(USA ,CA,AU,UK).other country 7-12 days (European, South America Africa,etc.).
Notes:
We will NOT be responsible for any delay during delivery including but not limited to customs postage checking, strike, force majeure etc
.
As a buyer, it is your duty to pay the tax when you make a order from abroad. Our price does not include taxes, VAT, or other hidden charges.
RETURNS
Warranty:
We guarantees new equipment other than accessories to be free fro
m
defects in workmanship and materials
for a period of 24 months ( 24months for spare parts)
from the date of shipment under normal use and service.Our company's obligation under this warranty is limited to repairing,at our company's option, any part which upon our company's examination proves defective.
If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
We will refund the money to you when we get the return items.Or replace item for you free of charge.
If buyer want to return for personal reason. The buyer will be in charge of the shipping cost.
If you are not satisfied with the product or service, please
contact me and don't give us negative or natural feedback,We must give you a satisfactory solution.
We are the manufacturer and distributor of medical equipment for more than 10 years. If you are interested in the distribution work, please feel free to contact us.
ABOUT US
We are the manufacturer and distributor of medical equipment
for
more than 10 years.
If
you are interested in the distribution
work, please feel free to contact us.
We will reply to you within48 hours. Please kindly wait for
us
.
During the duty time ,we can give you a quick respond.If we are out of work ,please kindly be patient and considerable to give us
a little more time,not just leave the neutral or negative feedback without communication ,thank you for your cooperation !
We are the manufacturer and distributor of medical equipment for more than 10 years. If you are interested in the distribution
w
ork, please feel free to contact us.